IMPORTANT 

SAFETY RULES

Read, understand, and follow 

all instructions carefully before 

installing and using this product.

IMPORTANT!

DO NOT RETURN PRODUCT TO STORE

To purchase parts and accessories or to obtain non-technical assistance, Visit

 

www.intexcorp.com

For technical assistance and missing parts call us toll-free (for U.S. and Canadian Residents):

1-800-234-6839

Monday through Friday, 8:30am to 5:00pm Pacific Time

Don’t forget to try these other fine Intex products: Pools, Pool 
Accessories, Inflatable Pools and In-Home Toys, Airbeds and 
Boats available at fine retailers or visit our website listed below.
Due to a policy of continuous product improvement, Intex 
reserves the right to change specifications and appearance, 
which may result in updates to the instruction manual without 
notice.

249-*PO-R0-1804

For illustrative purposes only. 

Summary of Contents for ECO7111

Page 1: ... obtain non technical assistance Visit www intexcorp com For technical assistance and missing parts call us toll free for U S and Canadian Residents 1 800 234 6839 Monday through Friday 8 30am to 5 00pm Pacific Time Don t forget to try these other fine Intex products Pools Pool Accessories Inflatable Pools and In Home Toys Airbeds and Boats available at fine retailers or visit our website listed b...

Page 2: ... Instructions 7 10 Salt Pool Water Volumes 11 Intex Pools Salt Table 12 Intex Pools Cyanuric Acid Table 13 Intex Pools Operating Time Table 14 Non Intex Pools Salt Table 15 Non Intex Pools Cyanuric Acid Table 15 Non Intex Pools Operating Time Table 15 Operating Instructions 16 18 LED Code Chart 19 Maintenance 20 22 Long Term Storage 23 Pool Maintenance and Chemical Definitions 24 Troubleshooting G...

Page 3: ...d use only identical replacement parts Always unplug this product from the electrical outlet before removing cleaning servicing or making any adjustment to the product The unit is provided with a ground fault circuit interrupter GFCI To test the GFCI push the test button The GFCI should interrupt power Push the reset button power should be restored If the GFCI fails to operate in this manner The G...

Page 4: ...s and become familiar with all the parts NOTE Drawings for illustration purpose only Actual product may vary Not to scale No tools are required for the assembly 1 2 3 4 6 5 8 8 7 1 2 10 9 34 13 14 15 12 16 17 30 35 18 11 12 31 33 If this pump was not purchased as part of a pool set the above parts can be ordered at www intexcorp com if needed Parts shown on this page are supplied with the pool pac...

Page 5: ...OSE WITH COLLAR AND 2 HOSE CLAMPS 1 11583 10 SCREW 2 11519 11 FLOW SENSOR 1 11460 12 ELECTROLYTIC CELL NUT 2 11582 13 ELECTROLYTIC CELL O RING C INCLUDED 1 11906 14 E C O ELECTRODE 1 11900 15 L SHAPE O RING 1 11228 16 O RING C 1 10712 17 ANGLE JOINT O RING D INCLUDED 1 11584 18 O RING A 1 11587 19 PLUNGER VALVE HOSE O RING STEP WASHER INCLUDED 2 10747 20 HOSE O RING 2 10262 21 STEP WASHER 2 10745 ...

Page 6: ...ter and instantly starts destroying bacteria and algae It also oxidizes all other organic materials The Electrocatalytic Oxidation E C O is an Advanced Oxidation Processes AOPs When direct current is applied to the electrocatalytic oxidation electrodes water will be discharged to generate hydroxyl radicals The hydroxyl radical is a powerful oxidant which oxidizes organic contaminants and destroys ...

Page 7: ...idge is being placed or cleaned If your pool has an inflatable top ring install the strainer nozzle and plunger valve before inflating the pool liner top ring The parts numbers here onward refer to the parts depicted in the Parts List section of this manual To install do the following IMPORTANT The Saltwater System Filter Pump must be installed as the last piece of pool equipment in the water retu...

Page 8: ...ded connector 24 Leave the flat washer 23 on the connector 24 3 Install the strainer and plunger valve at the lower position of pool outlet marked From the inside of the pool liner insert the connector 24 into one of the pre cut holes with the washer remaining on the connector to be placed against the inside of the liner wall 4 Before assembly lubricate the threads with a petroleum jelly Then with...

Page 9: ...ll 4 Before assembly lubricate the threads with a petroleum jelly Then with the flat side of the strainer nut 22 facing the outside wall of the liner in a clockwise motion screw the strainer nut 22 back onto the inlet threaded air connector 37 see drawing 6 5 Finger tighten the adjustable pool inlet jet nozzle 25 and the strainer nut 22 onto the inlet threaded air connector 37 6 Grasp the plunger ...

Page 10: ... is an airtight system In a counter clockwise motion turn both air release valves 1 7 1 2 turns to open DO NOT remove air release valves as water will expel with force if the motor is turned on and injury may occur 6 Grasp and remove the filter housing cover 4 Check to see if a cartridge is inside the housing If yes replace the cover finger tighten the housing collar 3 back onto the filter housing...

Page 11: ... pool Salt is not lost due to evaporation Adding Salt 1 Switch on the unit then press and hold both and button for 5 seconds the LED flashes FP The unit is now in a Filter pump working mode and switch the filter pump on to start the water circulation 2 Keep the saltwater system turned off 3 Determine the amount of salt to be added see Salt Table 4 Evenly spread the proper amount of salt around the...

Page 12: ...4 14209 95 45 25 10 488cmx122cm 16 x48 4273 16173 110 50 30 15 488cmx132cm 16 x52 4614 17464 115 50 30 15 549cmx107cm 18 x42 4786 18115 120 55 30 15 549cmx122cm 18 x48 5455 20647 135 60 35 15 CIRCULAR METAL FRAME POOL 457cmx91cm 15 x36 3282 12422 80 35 20 10 457cmx107cm 15 x42 3861 14614 100 45 25 10 457cmx122cm 15 x48 4440 16805 110 50 30 15 488cmx122cm 16 x48 5061 19156 125 55 35 15 549cmx122cm ...

Page 13: ...0 for Easy Set Oval Pool Cyanuric Acid Needed for Startup 0 03g L 30ppm Gals Liters Lbs Kgs INTEX ABOVE GROUND POOLS AGP s EASY SET POOL 457cmx84cm 15 x33 2587 9792 0 6 0 3 457cmx91cm 15 x36 2822 10681 0 7 0 3 457cmx107cm 15 x42 3284 12430 0 8 0 4 457cmx122cm 15 x48 3736 14141 0 9 0 4 488cmx107cm 16 x42 3754 14209 0 9 0 4 488cmx122cm 16 x48 4273 16173 1 1 0 5 488cmx132cm 16 x52 4614 17464 1 2 0 5 ...

Page 14: ...488cmx107cm 16 x42 3754 14209 4 5 6 488cmx122cm 16 x48 4273 16173 4 5 6 488cmx132cm 16 x52 4614 17464 5 6 7 549cmx107cm 18 x42 4786 18115 5 6 7 549cmx122cm 18 x48 5455 20647 6 7 8 CIRCULAR METAL FRAME POOL 457cmx91cm 15 x36 3282 12422 3 4 5 457cmx107cm 15 x42 3861 14614 4 5 6 457cmx122cm 15 x48 4440 16805 5 6 6 488cmx122cm 16 x48 5061 19156 5 6 7 549cmx122cm 18 x48 6423 24311 7 8 9 ULTRA FRAME POO...

Page 15: ... Water Capacity Liters x 0 003 Water Capacity Gals x 0 0067 Water Capacity Liters x 0 0008 CYANURIC ACID TABLE FOR COMMON NON INTEX POOLS Water Capacity Salt Needed for Startup Salt Needed when Low Salt Detected CODE 91 Gals Liters Lbs Kgs Lbs Kgs 2000 7500 50 20 10 5 4000 15000 100 45 25 10 6000 22500 150 65 40 20 7000 26500 175 80 55 20 Water Capacity Operating Time hours at different ambient ai...

Page 16: ... 1 7 When all the air has escaped water will flow out of the valves 1 7 When this occurs gently finger tighten the valves in a clockwise direction 5 Turn on the switch The filter pump is now filtering the water 6 The green Pump light on the control panel will light up that indicates the filter pump is running To prevent air lock open the lower plunger valve connected inlet hose first and then the ...

Page 17: ...ime from 01 to 12 hours maximum If you have selected too many hours keep pressing to repeat the cycle The built in timer will now activate your Saltwater System at the same time each day for the number of hours you have set NOTE The Saltwater System will not operate if the filter pump is not operating 3 Lock keypad controls With the desired hour value showing press button until you hear a beep The...

Page 18: ...3 The system is now in Stand By mode After a while it shuts down and sets itself in a Power Saving mode The system will automatically turn itself back on in 24 hours starting its daily cycle of chlorine production The SLEEP indicator stays on while the system is in the Power Saving mode The LED display however goes blank after 5 minutes Press any button or to view the last LED code 7 Running the p...

Page 19: ...vice must accept any interference including interference that may cause undesired operation of the device Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This equipment has been tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are d...

Page 20: ...then use a garden hose to wash it off 3 If flushing with water does not remove the deposits use a plastic brush to clean the surface and the hinge if necessary Do not use a metal brush 4 After the flow sensor has been inspected and cleaned align the locator notch on the flow sensor to the connection ridge in the conduit Now turn the collar in a clockwise motion tightening the sensor back into its ...

Page 21: ...f the pool 3 Disconnect the hose with nut 8 from the Saltwater System and assemble the cell cover 30 at the side of the cell 4 Unscrew the collar of the E C O electrode 14 and pull out the E C O electrode from the electrolytic cell 13 housing 5 Pour kitchen grade vinegar into the electrolytic cell 13 to immerse the titanium and E C O electrodes Soak for 1 hour 6 Open one side of the cell cover 30 ...

Page 22: ...sed filter cartridge 7 Examine the inside of the filter housing 8 If dirt or sediment is located on the bottom of the housing then A In a counter clockwise motion gently unscrew and remove the sediment valve 1 located at the bottom of the housing Place it in a safe place B With a bucket of water or a garden hose pour water into the housing flushing out the sediment C Screw back the sediment valve ...

Page 23: ... the color chart on the packaging label If necessary adjust the chemical level in the pool water It is very important to use the proper technique when testing the water s chemical level Read and follow the written strip instructions carefully 1 Disconnect the power cord from the electrical outlet 2 After the pool is completely empty disconnect the Saltwater System from the hoses by reversing the i...

Page 24: ... is Result if too low Corroded metals eye skin irritation destruction of total alkalinity Result if too high Scale formation cloudy water shorter filter runs eye skin irritation poor Chlorine efficiency Total Alkalinity Indicates the degree of the water s resistance to change in pH It determines the speed and ease of pH change so always adjust total alka linity before adjusting the pH level Result...

Page 25: ...ss A Ground Fault Circuit Interrupter or RCD Reset circuit breaker If circuit breaker trips repeatedly your electrical system may have a defect Turn off circuit breaker and call an electrician to correct the problem Let motor cool down Adjust the sanitizer and pH level Consult your local swimming pool supply stores Clean or replace cartridge Check the cartridge for holes Replace if damaged Operate...

Page 26: ...ncrease the daily Saltwater System operating time See Operating Instructions Check the salt level with the Test Kit Adjust as needed See Salt Pool Water Volumes Use a pool cover when the pool is not in use and or when the unit is operating Increase the daily Saltwater System operating time See Operating Instructions Remove the cell for inspection clean it if necessary See Maintenance Cover the poo...

Page 27: ...n of the inlet and the outlet hose Reverse the hoses if necessary See Set Up Instructions Clean the flow sensor paying special attention to the hinge See Maintenance Plug the flow sensor firmly into the flow sensor receptacle Reset both timers on the filter pump and saltwater system See Boost Cycle Contact Intex Service Center Remove the electrolytic cell for inspection Clean it if necessary See M...

Page 28: ...ations Demand constant supervision A competent adult should be appointed as a lifeguard or water watcher especially when children are in and around the pool Learn to swim Take the time to learn CPR and first aid Instruct anyone who is supervising pool users about potential pool hazards and about the use of protective devices such as locked doors barriers etc Instruct all pool users including child...

Page 29: ...rranty cover the item the item will be repaired or replaced at no charge Any and all disputes regarding the provisions of this Limited Warranty shall be brought before an informal dispute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject to the rules and r...