Menu button:
Pressing the Menu button in the start screen leads to a selection
menu. There are three sub-menus. The
arrow keys
can be used
to select the desired menu, which must then be confirmed using
the
Enter key
.
Settings
: The values for the outgoing air and temperature
hysteresis can be set in the Settings menu.
Operating data
: Used by the after-sales service to
display
but not change
the operating data of the device.
History
: Used by the after-sales service to
display but not
change
the runtimes of the compressor, the ventilator and
the outgoing air.
Preconfiguration:
Preconfiguration can be accessed by pressing the
Menu button
once in the
selection menu
. Preconfiguration can also be ac-
cessed by pressing the
Menu button
twice in the start screen.
Whether the device uses an
additional PWW heating re-
gister
or not can be set here.
When starting the device, the target value for the humidity is dis-
played by default.
7 Maintenance / Care
Proper maintenance and care are essential for faultlessoperation
and long service life of the device. Thus, maintenance checks
should be carried out at regular intervals(1 x year), and include
the followingprocedures:
Complete cleaning
Complete cleaning of the entiredevice should include the
ventilatorwheel, evaporator, condensate basin and condensate
outflow.
To protect the surfaces, avoid leaning anything against the de-
vice or putting objects on the device. External device parts can
be wiped with a damp cloth and domestic cleaner.
ATTENTION!
Never use cleaning agents containing sand, soda, acid or chloride as
these can damage the surfaces.
Condensate drain
Must be cleaned regularly fordeposit removal.
Ventilators
The bearings of the ventilator shaft are permanently lubricated.
Refrigerating circuit
Adjustment of the refrigerating circuit is carried out by the manuf-
acturer. For maintenance and potential repairs (only to be carried
out by authorized specialists), the following values to determine
the correct total fillingweight apply:
Supercooling (before expansion valve) approx. 2-3 K
Overheating approx. 4-8 K
(check via manometer and thermometer)
Ensure that the amount and condition of the air correspond to
theactual operating conditions.