Machine Component Terms
4-3
KVAL 994-X Operation Manual
Machine Component Terms
This table includes definitions of common terms.
Machine Terminology
Machine
Electrical Panels
Electrical Panels contain the brains and power for the machine. The
Main Electrical Panel contains the main PLC and servo drives. The
High Frequency Panels contain the VFD’s drive routers, width
adjust, and feed motors.
Door Clamp
The door clamp secures the door for stable routing and drilling.
Jamb Clamp
The jamb clamp secures the jamb to hold it in place as routing and
drilling.
Door Stop
The door stop sets the door in the correct position for processing.
Jamb Stop
The jamb stop sets a reference for the jamb to be in the correct posi
-
tion for processing. It is located on the front section of the machine
and is set manually by the operator.
Tools
Routers
Routers are located in the Carriage Heads and on the Back Section.
The routers rout the hinge pockets and rout face plates. Typically
Carriage Heads contain two routers that cut in the opposite direc
-
tions to create a smooth cut.
Bolt Drill
The bolt drill is located on the back section. Drills a bolt hole on the
lock edge of the door.
Lock Bore
The lock bore is located on the back section. It drills a lock hole on
the face of the door.
Pre-drills
The pre-drills are located in the Carriage Heads. They pre-drill screw
holes for hinge screw application on the door and jamb.
Chisels
(Opt CH)
Chisels are located in the Carriage Heads and the back section. The
chisels square the corners on the hinge pockets and the lock plate.
Chip-Out Block
Chip-Out Blocks are located under some drills to reduce tear-out on
the edges of the cut.
Operation
Operator’s Station
The Operator’s Station is the interface of operator and machine. It
contains power controls and touch screen interface to control the
cutting parameters of the door.
Machine Control
Located mid machine, manually set Feed (Auto-Man), LH or RH
door, Start and Stop machine.
Door Clamp Pedal
The Door Clamp Pedal is a foot pedal that activates the Door Clamp
to either clamp or unclamp the door.
Jamb Clamp Pedal
The Jamb Clamp Pedal is a foot pedal that activates the Jamb
Clamp to either clamp or unclamp the jamb.
Six-Shooter
The Six-Shooter is located at the left side of the machine. Six Shoot
-
ers apply hinges and the secures them with screws. (3x3 pattern)
Eight-Shooter
(Opt K)
The Eight -Shooter is located at the left side of the machine.Eight
Shooters apply hinges and the secures them with screws. (4x4 pat
-
tern)
Содержание 994-X
Страница 4: ...KVAL 994 X Operation Manual ...
Страница 29: ...How to Download the Service Application 1 21 KVAL 994 X Operation Manual Page Intentionally Left Blank ...
Страница 82: ...Calibration of the Back Section KVAL 994 X Operation Manual 3 22 ...
Страница 124: ...KVAL 994 X Operation Manual 4 42 ...
Страница 128: ...Index Kval 994 X ...
Страница 129: ......