Option: Checking Screw Delivery
4-35
KVAL 994-X Operation Manual
Option: Checking Screw Delivery
Sensors on each feed tube, monitors the screw delivery to the Six Shooter or Eight Shooter. If
screws do not pass by the sensors, a red light located on the six shooter will turn on.
A popup dialog box will be displayed on the interface screen identifying the error tubes. Investi
-
gate and repair. After screws are cleared, continue with process.
Screw Delivery Sensors:
Ferro sensors located on
each tube.
Fail Indicator Light:
If a screw is not delivered to
the index of the six shooter
this light will turn on.