FC244/D/-FF/D-FF
140
11. - Troubleshooting guide
KN329CGB_A
Mower conditioner
- Lower the tractor lift linkage in working position.
- Activate the tractor’s dual-action distributor to
lower the mowing unit to the ground.
- Operate tractor single acting valve to increase
the pressure in the circuit.
- Inflate the hydraulic circuit to 80 bar (1160 psi):
Refer to the decal fitted on the machine.
- Shut-off valve using 18 box wrench supplied with
the machine.
- Activate the tractor double acting valve in the
headland turn position direction.
In headland turn position:
• The distance between hitch pin axis and
the ground must be of (500 mm (1’8’’).
K9C470TL 0