10. - Maintenance and storage
KN329CGB_A
Mower conditioner
-
The fixing bolts should be changed in the
following cases:
• (a): When there is visible distortion.
• (b): When the locking compound is worn or
inoperational.
• (c): When there is only X = 2 mm (0.08’’) material
left between the bolt head and body.
• (d): When diameter D of the bolt shoulder is less
than 11 mm (0.43’’).
a
b
c
d
D
X
See section: Maintenance and storage /
Maintenance / Inspection of knives and securing
elements / Disc replacement.
Slightly hit all ground residues between the
knife and the screw with a mallet to remove
them.