8. - Instructions for work
KN041BGB A
Mower conditioner
Setting the ground pressure of the mowing
unit
The following adjustments do not cause the
machine to move.
- Place the machine in working position.
- Connect hydraulic hose (1) of the floatation system
to a single acting valve.
- Open the valve using 18 box spanner supplied with
the machine.
- Activate tractor hydraulic spool valve until required
pressure is shown on gauge (2).
K9C420TL 0
1
2
K9C420TL 0
Refer to the decal fitted on the machine.
P
P MIN
bar (psi)
bar (psi)
P MAX
bar (psi)
FC 243 GII
FC 243 RGII
FC 283 GII
FC 283 D
FC 283 RGII
72 (1044)
85 (1233)
75 (1088)
74 (1073)
74 (1073)
85 (1233)
95 (1378)
95 (1378)
90 (1305)
90 (1305)
90 (1305)
80 (1160)
82 (1189)
82 (1189)
105 (1523)
K9C094TL 0