10. - Maintenance and storage
FC243RGII
73
KN041BGB A
Mower conditioner
10.4 Maintenance
10.4.1 Hydro-pneumatic accumulators
Before adjusting, maintaining or repairing
the machine, turn off ignition key and wait
until all moving parts have come to a
complete stop.
Prior to carrying out work on a circuit
comprising a hydro-pneumatic accumulator,
depressurize the circuit.
It is strictly forbidden to weld, grind or drill
onto a hydro-pneumatic accumulator.
- Regularly check the tightness of the accumulator
fixing bolts and that the hydraulic circuit is leak-free
(a small oil leak can change settings).
Replace the hydro-pneumatic accumulator
every 10 years.
Checking of hydro-pneumatic accumulators:
- Conform with the regulations of the
country regarding pressurized equipment.
(Hydro-pneumatic accumulator of a capacity
exceeding or equalling 1 L (0.26 US gal)).
Содержание FC243RGII