Operation of the Quantron E2
83
4
Test/Diagnosis; example: slide
1.
Switch from the
System/Test
menu to the
Test/Diagnosis
submenu.
2.
Highlight the desired function and press the
enter key
.
The status of the sensors/actuators is displayed.
Figure 4.53:
Test/Diagnosis; example: slide
[1]
Position display
[2]
Signal display
[3]
Function keys for right actuator
[4]
Function keys for left actuator
The status of the signal for the left and right hand side is displayed separately by
means of the signal display.
The actuating mechanism can be moved using the function keys
F1 - F4
.
n
CAUTION
Risk of injury due to moving machine parts!
During the tests, machine parts may start to move automatically.
Ensure that there is no one the area of the mineral fertilizer
spreader before carrying out the tests.
4
1
2
3