Operation of the Quantron E2
29
4
When weighing the quantity, ensure that:
the fertiliser spreader is at a standstill,
the PTO is switched off,
the mineral fertiliser spreader is in a horizontal position and off the ground,
the tractor is at a standstill,
the Quantron E2 is switched on.
Weighing the fertiliser quantity in the hopper:
1.
Fill the hopper.
A window appears in the display which shows the remaining fertiliser
quantity.
2.
Highlight the type of filling carried out on the display:
Refill
: Continue spreading with the same fertiliser.
New fertiliser
: Flow factor is set to 1.0 and a new flow factor regulation will
follow.
ESC
: Quit
3.
Confirm with the
enter key
.
The operating screen appears on the display. The weighted quantity can
be displayed on the display field.
Figure 4.7:
Operating screen with weighed quantity
NOTICE
In order to display the remaining fertiliser quantity on the
operating screen,
the
display option
kg left
must be selected (
4.9.2: Display config., page 80
).