Operation of the Quantron E2
4
48
Recalculating the flow factor
1.
Weigh the discharged fertiliser quantity.
2.
Enter the weight of the discharged fertiliser quantity in the input field of the
Input collected weight
menu.
See also chapter
4.11.2: Input of values using the cursor keys, page 89
.
3.
Confirm the input by pressing the
enter key
.
The new value is saved in the control unit.
The display shows the
Flow factor calculation
menu.
Figure 4.23:
Flow factor calculation menu
[1]
Display of previously saved flow factor
[2]
Display of newly calculated flow factor
4.
Specify the flow factor.
To accept the
newly calculated
flow factor, press the
enter key
.
To confirm the
previously saved
flow factor, press the
ESC key
.
The flow factor is saved.
The fertiliser settings menu is displayed.
5.
Press the
ESC key
to return to the
previous menu
or
press the
menu key
to return to the
operating screen
.
NOTICE
The flow factor must lie between 0.4 and 1.9.
1
2