![Kübler SMC1.3 Скачать руководство пользователя страница 212](http://html1.mh-extra.com/html/kubler-0/smc1-3/smc1-3_safety-manual_2008430212.webp)
R60047.0002 - Index 2
EN – page 92 / 115
Continuation “
Response Time of the Frequency Error Evaluation
”:
Filtering effect with a frequency drop of 10 %
Div. Filter = 3 and Div. %-Value = 10:
tripping after 9 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 10:
tripping after 10 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 10: tripping after 10 x (Sampling Time or 1/f)
Filtering effect with a frequency drop of 20 %
Div. Filter = 3 and Div. %-Value = 20:
tripping after 13 x (Sampling Time or 1/f)
Div. Filter = 3 and Div. %-Value = 10:
tripping after 4 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 20:
tripping after 20 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 10:
tripping after 10 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 20: tripping after 20 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 10: tripping after 10 x (Sampling Time or 1/f)
Filtering effect with a frequency drop of 30 %
Div. Filter = 3 and Div. %-Value = 30:
tripping after 16 x (Sampling Time or 1/f)
Div. Filter = 3 and Div. %-Value = 20:
tripping after 7 x (Sampling Time or 1/f)
Div. Filter = 3 and Div. %-Value = 10:
tripping after 3 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 30:
tripping after 30 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 20:
tripping after 20 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 10:
tripping after 10 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 30: tripping after 30 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 20: tripping after 20 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 10: tripping after 10 x (Sampling Time or 1/f)
Filtering effect at a frequency drop of 40 %
Div. Filter = 3 and Div. %-Value = 40:
tripping after 18 x (Sampling Time or 1/f)
Div. Filter = 3 and Div. %-Value = 30:
tripping after 9 x (Sampling Time or 1/f)
Div. Filter = 3 and Div. %-Value = 20:
tripping after 5 x (Sampling Time or 1/f)
Div. Filter = 3 and Div. %-Value = 10:
tripping after 2 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 40:
tripping after 36 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 30:
tripping after 26 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 20:
tripping after 16 x (Sampling Time or 1/f)
Div. Filter = 5 and Div. %-Value = 10:
tripping after 6 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 40: tripping after 40 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 30: tripping after 30 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 20: tripping after 20 x (Sampling Time or 1/f)
Div. Filter = 10 and Div. %-Value = 10: tripping after 10 x (Sampling Time or 1/f)
Содержание SMC1.3
Страница 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Страница 49: ...R60047 0001 Index 2 DE Seite 49 120...
Страница 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Страница 118: ...R60047 0001 Index 2 DE Seite 118 120...
Страница 119: ...R60047 0001 Index 2 DE Seite 119 120...
Страница 131: ...R60047 0002 Index 2 EN page 11 115 4 3 SMC1 3 Block Diagram 4 4 SMC1 3 Connections The figure shows the available ports...
Страница 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Страница 168: ...R60047 0002 Index 2 EN page 48 115...
Страница 233: ...R60047 0002 Index 2 EN page 113 115 19 1 Dimensions incl SMCB on front Front Rear SMC2 4 SMCB option...