![Kübler SMC1.3 Скачать руководство пользователя страница 172](http://html1.mh-extra.com/html/kubler-0/smc1-3/smc1-3_safety-manual_2008430172.webp)
R60047.0002 - Index 2
EN – page 52 / 115
9.6
Wait Time
The Wait Time parameter defines the frequency below which all frequencies will be
taken as zero. Setting of e.g. 1.0 second will result in zeroizing all frequencies lower than
1 Hz. In this context it must be clarified whether the application requires a standstill- or
drift-monitoring or not.
1.
Where the application does not require any standstill or direction or drift control,
you are free to set Standstill Time with regard of the expected minimum
frequency and the required response time only.
2.
Where the application uses standstill control, please observe also possible jitter
during standstill and adjust Wait Time correspondingly.
3.
Where the application uses forward/reverse direction control, also possible jitter
should be considered while the system holds in closed loop position control.
No.
Parameter
Remark
001
“Wait Time”
Adjust the zero balancing window
9.7
F1-F2 Selection
This parameter is used to determine the base frequency. When the original frequency of
sensor 1 is higher than the original frequency of sensor 2, the parameter F1-F2-Selection
is set to 0, otherwise to 1. The higher frequency is used to set the switching points,
because it is more stable.
No. Parameter
Remark
003 „F1-F2
Selection”
When Frequenz 1 > Frequenz 2, parameter is set = 0 (F1 selected).
When Frequenz 2 < Frequenz 1, parameter is set = 1 (F2 selected).
Содержание SMC1.3
Страница 44: ...R60047 0001 Index 2 DE Seite 44 120 8 2 Montage Demontage...
Страница 49: ...R60047 0001 Index 2 DE Seite 49 120...
Страница 117: ...R60047 0001 Index 2 DE Seite 117 120 20 Zertifikat...
Страница 118: ...R60047 0001 Index 2 DE Seite 118 120...
Страница 119: ...R60047 0001 Index 2 DE Seite 119 120...
Страница 131: ...R60047 0002 Index 2 EN page 11 115 4 3 SMC1 3 Block Diagram 4 4 SMC1 3 Connections The figure shows the available ports...
Страница 163: ...R60047 0002 Index 2 EN page 43 115 8 2 Mounting Dismounting...
Страница 168: ...R60047 0002 Index 2 EN page 48 115...
Страница 233: ...R60047 0002 Index 2 EN page 113 115 19 1 Dimensions incl SMCB on front Front Rear SMC2 4 SMCB option...
Страница 234: ...R60047 0002 Index 2 EN page 114 115 20 Certificate...