EN 32/38
Manual
Limes LA50 / BA5
Absolute Magnetic Length Measurement System
Default settings on delivery
Devices with cable outlet
Description
Setting
Software
Baud rate
250 kBit/s
Object 2100h = 05h
Node address
1
Object 2101h = 01h
Termination
on
by rotary switch
7.4 Termination independence
As standard the interfaces CANopen, is supplied with a termination impedance of 120 Ω inside
of the interface input. The termination impedance can be deactivated with the S3 switch. The
SSI interface is also supplied with an integrated termination impedance.
Example „emulation switching“
In order to deactivate the termination impedance switch S3 use micro- screwdrivers counter-
clockwise.
Position of the switch:
Termination impedance: OFF
Position of the switch:
Termination impedance: ON