7. Design and Functions
7.1 Connections and Interfaces
The following chapters give detailed informations about connections and interfaces.
7.2 Interface SSI
Principle of the function: If the clock is not interrupted for the time Tm-T/2 (output of further
25 periods), the shift register clocks once again the same data value (error recognition in
evaluation).
Some encoders contain a Power Failure Bit (PFB):
With LA50 the PFB is always „low“.
Not inverted SSI clock
Figure 5: Readout of data (2-time with 25 clocking)
By using the decoding switch, which is located behind a protection cap on the top of the
sensor, the data format of the SSI interface can be changed over with the help of a micro
screwdriver from Binary code to Gray code.
Gray/Binary
Switch
LED
Position
Code
1
Binary
0
Gray*
*default
PFB = Power failure bit
T = Cycle duration of clock pulse
Tm = Monoflop time > 15 μs