DATAFLEX
®
42/1000
Torque Measuring Shaft
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
49016 EN
12 of 21
2
Please observe protection
note ISO 16016.
Drawn:
2017-01-02 Shg/Koe
Replaced for:
KTR-N dated 2015-04-13
Verified:
2017-01-02 Shg
Replaced by:
Fixing the housing
!
The housing must be protected from rotation. For that purpose there is a thread size M4 at
the bottom side. Please make absolutely sure to avoid a rigid fixing of the housing!
!
Opening the housing is not required and may cause damage to the measurement shaft.
Degree of protection
All DATAFLEX
®
measuring shafts type 42/1000 correspond to protection class IP51 according to
DIN EN 60529.
Maintenance
The DATAFLEX
®
measuring shaft is maintenance-free. Lubrication or cleaning is not necessary.
Calibration
The transducer is calibrated when being supplied. We recommend an annual inspection of the calibration.
1. General description
The measuring shafts type DATAFLEX
®
42 are provided with wire strain gauges (DMS) the signals of which are
transmitted contactless.
In addition, a two-channel shaft encoder provides two speed signals shifted by 90 degrees. Each signal has a
resolution of 720 periods per revolution. The measuring shaft is connected to the connection housing DF2 via the
connection cable which is available as an accessory.
The measuring shaft should not be switched on before all connections have been properly
connected. After initial switch-on the measuring shaft needs about 5 minutes until the
warm-up period is finished and the measurement device has its standard accuracy.
4
Assembly
4.9 Advice for assembly of the DATAFLEX
®
torque measuring shaft
4.10 Technical description