DATAFLEX
®
42/1000
Torque Measuring Shaft
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
49016 EN
16 of 21
2
Please observe protection
note ISO 16016.
Drawn:
2017-01-02 Shg/Koe
Replaced for:
KTR-N dated 2015-04-13
Verified:
2017-01-02 Shg
Replaced by:
Output circuit (connection N1 and N2)
The speed outputs N1 and N2 have short-circuit proof push-
pull outputs providing a square-wave voltage with an ampli-
tude of 24V and a maximum switching current of 30 mA. The
output terminals must not be charged with an external voltage
(see illustration 18).
The output voltage of speed lines and torsional direction line
can be varied by modifying the jumper position in the connec-
tion housing to 5V level (see illustration 19).
Illustration 18: Output circuit of speed outputs
Illustration 19: Modification of voltage level for the speed signal/direction signal
4
Assembly
4.10 Technical description