DATAFLEX
®
42/1000
Torque Measuring Shaft
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
49016 EN
15 of 21
2
Please observe protection
note ISO 16016.
Drawn:
2017-01-02 Shg/Koe
Replaced for:
KTR-N dated 2015-04-13
Verified:
2017-01-02 Shg
Replaced by:
d) Speed signals N1, N2, N-U, R/L (No. 1, 3, 7, 9)
The connection housing DF2 has 4 connections
for speed output:
- Two square-wave signals shifted by 90 de-
grees (N1, N2)
- A scalable voltage output (N-U) with direction
signal (R/L)
Illustration 15
Outputs N1 and N2
Each of the speed outputs N1 and N2 provide a square-wave signal with a resolution of 720 periods per revolu-
tion (illustration 16).
Illustration 16
The speed is calculated as follows:
N [rpm] = f [Hz] / 12
The speed channel signals N1 and N2 have a phase shift of 90 degrees to each other. Depending on the rota-
tional direction one of the two signals leads 90° in phase (illustration 17).
Clockwise
Illustration 17
4
Assembly
4.10 Technical description