5 Installation at Site
21 of 52
KSB SuPremE
Outdoor installation
For installation or storage in an outdoor environment, shield the drive by
implementing suitable protection measures in order to prevent condensation from
forming on the electronics and to avoid the long-term effects caused by direct
exposure to sunlight, rain, snow, ice and dust.
Flatness tolerance of contact surfaces
The motor feet can be dismantled from motors with a shaft centreline height of up
to 160 mm. Motors with a shaft centreline height of 160 mm or greater have
integrally cast feet, which is why their range of mounting arrangements is limited.
Table 13:
Flatness tolerance of contact surfaces for motor feet
Shaft centreline height
Flatness tolerance (mm)
≤ 132 mm
0,10
≥ 160 mm
0,15
Ventilation
WARNING
Improper installation
Drive overheated!
▷
Maintain the specified minimum distances to neighbouring assemblies.
▷
Never restrict the ventilation ducting to/from the drive.
▷
Prevent exhaust air from neighbouring assemblies from being drawn in directly.
X
Fig. 2:
Minimum distance X
Table 14:
Minimum distance X to neighbouring assemblies
Motors with shaft centreline height [mm]
Minimum distance X [mm]
71 - 100
30
112 - 132
40
160 - 180
50
200 - 225
60
Condensation water drain
If a drain hole is provided, position the motor in such a way that the water drain plug
is at the lowest point of the housing. The motor is supplied with the water drain plug
closed.
5.3 Installing the motor or electric drive
Checks prior to installation work
▪
Repair any damage to the paintwork. (
▪
Use white spirit to remove any anti-corrosives applied to exposed metal parts
that are required to ensure proper assembly and/or installation.
Alignment and fastening
NOTE
Maintain the vibration levels to ISO 10816-1 during operation.
Содержание SuPreme Series
Страница 1: ...Synchronous Reluctance Motor KSB SuPremE Installation Operating Manual ...
Страница 49: ......
Страница 50: ......
Страница 51: ......