5 Installation at Site
24 of 52
KSB SuPremE
Connecting the motor
U1
V1
W1
U2
V2
W2
U
V
W
Frequency inverter
KSB SuPremE B
PE
PE
Fig. 3:
Terminal wiring diagram
1. Check the output voltage of the frequency inverter against the data on the
motor name plate.
2. Knock out any knock-out openings in the terminal box. While doing this, avoid
causing damage to the terminal board, cable connections, etc. inside the
terminal box.
3. The motor is permanently wired in a star configuration. Terminals U2, V2 and
W2 are not connected. Connect the motor terminals U1, V1 and W1 to terminals
U, V and W of the relevant frequency inverter.
4. Connect the earth conductor (PE).
Table 16:
Compatible conductor cross-section
Motor size
Max. compatible conductor cross-section
[mm²]
71M ... 80M
4
90S ... 160M
6
160L
16
180M/L
25
200L ... 225M
50
Table 17:
Bolt size of earth conductor (PE)
Shaft centreline height [mm]
Thread size for earth conductor
71 ... 112
M 5
132 ... 180
M 6
200 ... 225
M 8
5.4.2 Version with connector contact and/or conductors
NOTE
This version is designed exclusively for mounting and connecting a PumpDrive 2 and
must not be used for any other purpose.