3 Transport/Temporary Storage/Disposal
11 of 52
KSB SuPremE
If condensation water has formed and a drain hole is provided, position the motor in
such a way that the water drain plug is at the lowest point of the housing. Drain off
the condensation water. (
Drain off the condensation water as required by the ambient conditions but at least
every 6 months.
Outdoor storage
CAUTION
Damage during storage due to humidity, dirt or vermin
Corrosion/contamination of the drive!
▷
Cover all components with water-proof material. Covers or tarpaulins must not
contact the surface of the stored goods.
▷
Ensure sufficient air circulation, e.g. by inserting wooden spacers.
▷
To ensure protection against ground moisture, arrange motors and packaged
motors on pallets, bars or foundations.
▷
Prevent the possibility of the product sinking into the ground.
Implement appropriate measures to accommodate extreme climatic conditions, e.g.
salty and/or dusty, moist atmospheres.
Indoor storage
Storage rooms should provide protection against extreme weather conditions and be
dry, dust-free, frost-free, jolt-free, vibration-free and well ventilated.
Storage of motors of type of construction X2 with mounting plate for PumpDrive 2
For storing a motor of this type of construction please note that when the frequency
inverter is not mounted, the motor's enclosure is IP40. Protect the connection
provided at the motor from the ingress of moisture and dust.
3.4 Disposal
Electrical or electronic equipment marked with the adjacent symbol must not be
disposed of in household waste at the end of its service life.
Contact your local waste disposal partner for returns.
If the used electrical or electronic equipment contains personal data, the user is
responsible for deleting it before the equipment is returned.
Due to some components, the product is classified as special waste.
1. Dismantle the product.
2. Separate and sort the materials, e.g. by:
- Metals
- Plastics
- Electronic waste
- Greases and other lubricants
3. Dispose of materials in accordance with local regulations or in another
controlled manner. PCBs, power electronics, capacitors and electronic
components are all hazardous waste.