5 Installation at Site
25 of 52
KSB SuPremE
Fig. 4:
Example of connection via connector contact
On the KSB SuPremE X2 variant, the top of the motor is prepared at the factory for
mounting PumpDrive 2.
Table 18:
Overview of possible connection types
Design
Connection via ...
KSB SuPremE X2 up to 4.0 kW
Mounting plate with connector contact
KSB SuPremE X2 5.5 kW and higher
Mounting plate with conductors
KSB SuPremE X2
up to 4.0 kW
Motors with a nominal power of 4 kW are electrically connected via a connector
contact. The connector features a guide tab to provide reverse polarity protection.
The guide tab points in the direction of the fan hood.
U1
V1
W1
PTC 1
PE
PTC 2
Fig. 5:
Pin assignment of the connector
KSB SuPremE X2
5.5 kW and higher
The mounting plate of units rated for 5.5 kW or higher has a cable gland for the
phase conductors and the earth conductor plus 2 PTC connection wires. These are
directly connected in the terminal wiring compartment of PumpDrive 2 according to
their marking or colour coding.
Table 19:
Colour coding
Connection
Colour code 1
Colour code 2
U
Blue
Red
V
White
Brown
W
Red
Yellow
Earthing
Green/yellow
Green/yellow
PTC1/2
Black
Black
In case of doubt, the labelled identification strips on the strands apply.
NOTE
The mounting plate with conductors is designed exclusively for mounting and
connecting a PumpDrive 2 with a rated power in excess of 4 kW and must not be
used for any other purpose.