The most common installation of the device enables it to draw air from rooms with a lot of
excess heat. A part of heat is drawn from this air and then released into the surroundings. The
air in kitchens, washing or sanitary rooms often has unpleasant odours, this is why it is released
into the surroundings. Here we must be careful to equalise the air flows and pressures in the
rooms; this has to be taken care of by the responsible ventilation design engineer.
CAUTION
The device cannot be installed on a location where air is polluted with toxic agents
which could damage the device (stables, warehouses with dangerous substances,
outdoors ...)
5.1 Minimal clearance from the device
The device can be installed in a room with installed air ducts or without them. This influences
the minimal clearance of the device from the walls; these depend on the direction of air
intake and outlet (chapter 5.4).
D
B
A
C
A
C
Picture 5: Minimal clearance from the walls
*If both air ducts are turned upwards, it is necessary to prevent the outlet and intake air to mix; this could lead to a
so-called “short-circuit” between outlet and intake air which significantly lowers the device’s performance. This is
why we recommend adding a bend on the outlet air connection and turn the outlet air away from the intake air.
Air intake
Φ
180
Air outlet
Φ
180
A [mm]
B [mm]
C [mm]
D [mm]
Without
bend
With bend
on the
outlet
Without
bend
With bend
on the
outlet
On
the
side
On
the
side
1000
250
90
90
200 / 250**
70
On
the
side
Above
60
60
1000
250
200 / 250**
70
Above
On
the
side
1000
250
200
200
200
70
Above
Above
60
60
/*
250
200
70
Содержание WP2 LF-202B