VII - 7
Maintenance
7.6
Maintenance instructions for the
hydraulic system
7.6.1 High-pressure filter
All Series Titan loading wagons with the operator-
friendly hydraulic unit are fitted with a high-pressure
filter in the high-pressure pipework to the valve unit.
Change the filter (3) after each season.
Changing the filter element
•
Switch the hydraulic system to the non-pressurised
state.
Place a vessel of sufficient capacity
underneath to hold the escaping oil.
•
Slacken the filter bottom section (4) using screw
wrench SW27.
•
Remove the filter bottom section (4) and shake out the
remaining oil.
•
Clean the filter bottom section (4).
•
Pull out the old filter element (3).
•
Push the new filter element (3) onto the valve collar.
•
Check the O-ring (2) on the filter bottom section (4).
If the O-ring is damaged, replace it with a
new one.
•
Replace the filter bottom section and screw it in.
•
Tighten to the end stop in the filter top section (1).
•
Pressurise the hydraulic system and check for leaks.
OUT
IN
4
3
5
2
1
Содержание Titan 6/50 GL
Страница 4: ...Foreword ...
Страница 8: ...Contents A1 3 Assembling the superstructure A 7 A2 Electrical circuit diagram A 10 ...
Страница 12: ...I 4 General information ...
Страница 17: ...II 5 Safety ...
Страница 20: ...II 8 Safety TR200022 1 7 7 4 2 9 5 3 6 TR200020 3 3 7 4 9 8 5 6 7 LinkeMaschinenseite RechteMaschinenseite ...
Страница 24: ...II 12 Safety ...
Страница 41: ...III 17 Operation KDW03210 1 Arrest the short cut loading wagon by applying the parkingbrake 1 ...
Страница 42: ...III 18 Operation ...
Страница 80: ...IV 38 Comfort Control Unit ...
Страница 86: ...VI 4 Hydraulic system 6 2 3 Hydraulic unit standard ...
Страница 87: ...VI 5 Hydraulic system 6 2 4 Hydraulic unit operator friendly ...
Страница 90: ...VI 8 Hydraulic system ...
Страница 110: ...VIII 2 Overwintering ...
Страница 112: ...IX 2 Recommissioning ...
Страница 114: ...X 2 Faults causes and removal ...
Страница 133: ...A 19 Appendix ...