16
Maintenance
16.22 Servicing compressed air brake (for version with "Compressed air brake")
192
Comprima V 180
Original Operating Instructions 150001053_00_en
DVG000-014
Shut down and safeguard the machine,
.
WARNING! Risk of eye injury due to spurting condensation water! Wear suitable
protective goggles.
ü
A suitable container is available for escaping condensation water.
Open the drain valve (2).
Æ
Allow compressed air and condensation water to escape out of the compressed-air tank (1).
Visually inspect the drain valve (2) to ensure that it is not defective or soiled.
Æ
If the drain valve (2) is defective and is no longer sealed, immediately have the drain
valve (2) replaced by a KRONE service partner.
Æ
If the drain valve (2) is soiled, clean the drain valve (2).
16.22.3
Retighten tensioning straps at the compressed air tank
DVG000-015
Shut down and safeguard the machine,
.
Check that the tensioning straps (1) are firmly attached.
If the compressed-air tank cannot be turned by hand, the tensioning straps (1) have been
correctly set.
If the compressed-air tank can be turned by hand, the tensioning straps (1) must be
retensioned.
To tension the tensioning straps (1), tighten the nuts (2).