
Maintenance
16
Servicing compressed air brake (for version with "Compressed air brake") 16.22
Comprima V 180
Original Operating Instructions 150001053_00_en
191
Removing filter element
ü
The machine is shut down and safeguarded,
.
Remove the clasp locking ring (8).
Take out the cover cap (7).
Take out the seal ring (6).
Take out the spring (5).
Take out the spacer (4).
Take out the filter element (3) with the spring (2).
Cleaning air filter
ü
The filter element has been removed,
Blow out the intrior of the filter housing, the filter element and the remaining components
with compressed air.
In the case of stubborn dirt, clean the components with water.
Installing filter element
ü
The machine is shut down and safeguarded,
.
Insert the filter element (3) with the spring (2).
Insert the spacer (4).
Insert the spring (5).
Insert the seal ring (6).
Insert the cover cap (7).
Mount the clasp locking ring (8).
16.22.2
Drain condensation water from the compressed air tank
WARNING
Risk of injury from corroded or damaged compressed air reservoirs
Damaged or corroded compressed air reservoirs may burst and cause serious injuries.
Observe the inspection intervals according to maintenance table,
.
Have damaged or corroded compressed air reservoirs replaced immediately by a
specialist workshop.
NOTICE
Damage to compressed air reservoir caused by water in the compressor unit
Water in the compressor unit leads to corrosion which damages the compressed air reservoir.
Check and clean drain valve according to maintenance table,
.
Immediately replace a defective drain valve.