KRONE Operation Unit Alpha
99
Pos: 42.41 /Ü berschriften/Ü berschriften 3/P-T/SSensortest digital @ 55\mod_1294752559156_78.docx @ 534106 @ 3 @ 1
8.1.7
Sensor Test Digital
Pos: 42.42 /WH B/Elektri k/R undballenpresse/Alpha (Medium) /Sensortest digital @ 83\mod_1317108532724_78.docx @ 726779 @ @ 1
In the sensor test the sensors fitted on the machine are tested for their digital condition.
A B
C D
E F
G H
2
3
6
7
8
10
RPM00003
Fig. 73
1. When switching operation on, keep the
key pressed.
The pilot lamp (6) flashes slowly.
The LEDs of the bar graph (11) indicate whether the sensors are alive (iron in front of the
sensor).
• LED ON:
Iron in front of the sensor
• LED OFF:
No iron in front of the sensor
• LED flashing: Cable break on the sensor
Refer to the following table for the assignment of the sensors.
LED Bar Graphs
Sensor
A
free
B
free
C
free
D
Slip
E
Filling left
F
Filling right
G
Net length
H
Net roll
Note
You can use the
and
keys to switch back and forth between “Sensor Test /
Analogue” and “Sensor Test / Digital”.
Pos: 42.43 /Layout Module /---------------Seitenumbr uch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Содержание Comprima F 125
Страница 385: ...150 102 161 00 Comprima F 125 F 155 1 3 5 5 6 1 2 3 ...
Страница 387: ...150 102 161 00 Comprima F 125 XC F 155 XC 2 3 1 3 5 5 A A1 P K3 K1 7 7 3 A B A A1 P K21 K20 1 ...
Страница 389: ...150 102 247 00 Comprima V 150 V 180 1 3 4 T P 50 180 bar ST A MS 1V1 S F R F R 1V1 Q30 6 5 5 3 1 T 1 2 ...
Страница 399: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ 5XQGEDOOHQSUHVVH 53 RPSULPD 9 1 ...
Страница 425: ......