7
Terminal menus
7.25
Menu 15 "Settings"
62
RP701-10 , RP701-11 , RP701-20 , RP701-21 , RP701-30 , RP701-31 , RP701-40 , RP701-41 , RP701-51
Comfort 1.0_en
ü
The blade cassette (2) is flush with the cutting unit housing (1).
Remove contamination in the area of the blade cassette (2) and the cutting unit housing (1).
Adjust sensor B08 “Blade cassette up” (3) in menu 15-1 “Sensor test”,
7.25.1.2
Adjusting sensor B09/B10 “Filling display left/right”
Comprima F
15-1
1
state:
5,0V
1,5V
1,0V
1,0V
1,0V
B08
B09
L
B10
R
2
1
3
EQG003-041
The sensor (3) is located behind the rear side guard:
•
B09 on the left side of the machine
•
B10 on the right side of the machine.
The green bar in menu 15-1 “Sensor test” shows the saved value. The black bar shows the
current value of the sensor. As soon as a new value is saved, the green bar is adjusted to the
black one.
ü
The bale chamber is closed and empty.
ü
Menu 15-1 “Sensor test” is open.
ü
Sensor B09 or B10 has been selected.
If the bar (2) is not inside the rectangle (1) when the bale chamber is closed and empty, adjust
sensor B09 or B10 mechanically:
Loosen the screw connections of the sensor and move it in the oblong hole until the bar (2)
is inside the rectangle (1) of the bargraph in the display.
ð
An audio signal sounds if the bar (2) is inside the rectangle (1).
Tighten the screw connections on the sensor.
Press
.
Æ
The set position is saved.
INFORMATION
Saving is only possible if the bar (2) is inside the rectangle (1) of the bargraph.
Содержание Comprima F 125
Страница 385: ...150 102 161 00 Comprima F 125 F 155 1 3 5 5 6 1 2 3 ...
Страница 387: ...150 102 161 00 Comprima F 125 XC F 155 XC 2 3 1 3 5 5 A A1 P K3 K1 7 7 3 A B A A1 P K21 K20 1 ...
Страница 389: ...150 102 247 00 Comprima V 150 V 180 1 3 4 T P 50 180 bar ST A MS 1V1 S F R F R 1V1 Q30 6 5 5 3 1 T 1 2 ...
Страница 399: ... LUFXLW GLDJUDP GRFXPHQW QR YHUVLRQ 5XQGEDOOHQSUHVVH 53 RPSULPD 9 1 ...
Страница 425: ......