Malfunctions - Causes and Remedies
367
Pos: 246.7 /BA/Störungen - Ursachen und Behebung/Ladewagen/Tabellarische Auflistung Teil2 Ladewagen @ 115\mod_1339743171429_78.docx @ 1012838 @ @ 1
Malfunction
Possible cause
Remedy
Increased blade breakage; more
force must be applied for the
blade control system
Safety rollers of single blade
locking device move sluggishly
The safety rollers must turn easily
during the selection (see section
on Maintenance "Checking the
Safety Rollers of Individual Knife
Retention")
Blade safety device zu hart 140
mm
Adjust the response threshold
weaker (refer to chapter Cutting
system “Setting the single blade
locking device (response
threshold)”)
Hydraulic system not working
System screw on the hydraulic
valve block not set correctly
Check the setting and change if
necessary
Power supply interrupted
Check the connections of the
electromagnetic valves and
perform a function test of valves
with hydraulic emergency
activation
Bad chop quality
Dull blades
Regrind or replace blades
P.T.O. speed too high
Reduce P.T.O. speed
Swath size too small
Increase swath or increase driving
speed
The crop is lying in the direction of
travel due to mowing
Align the crop perpendicular to
the direction of travel by swathing
again
Blade safety device set too weak
(blades elude too early)
Adjust the response threshold
higher (refer to chapter Cutting
system “Setting the single blade
locking device (response
threshold)”)
Pos: 246.8 /BA/Störungen - Ursachen und Behebung/Ladewagen/Störung_Ursache_Behebung Medium_Ausführung @ 31\mod_1252059241050_78.docx @ 303118 @ @ 1
Malfunction
Possible cause
Remedy
During unloading operation with
activated cross conveyor, the floor
conveyor supply is not activated
by pressing key (12) once, but the
key (12) is inching.
The setting of parameter “Cross
conveyor” is wrong.
Call up the sensor test, check the
parameter “Cross conveyor ” and
set if necessary.
Pressure builts up with activated
hydraulic, but there are no
functions carried out when
pressing the medium keys.
The setting of parameter “Load-
Sensing” is wrong.
Call up the sensor test, check the
parameter “Load-Sensing” and
set if necessary.
Pos: 247 /Layout Module /---------------Seitenumbruch---------------- @ 0\mod_1196175311226_0.docx @ 4165 @ @ 1
Содержание AX 250 D
Страница 330: ...Maintenance hydraulic system 330 18 6 Circuit Diagram of the Hydraulic System Comfort Electronics Fig 209 ...
Страница 332: ...Maintenance hydraulic system 332 18 7 Hydraulic circuit diagram cross conveyor medium electronic system Fig 210 ...
Страница 334: ...Maintenance hydraulic system 334 18 8 Hydraulic circuit diagram cross conveyor comfort electronic system Fig 211 ...
Страница 397: ......
Страница 398: ...01 2 3 4 5 6 7 6 8 1 95 76 1 6 7 9 0 1 2 3 4 5 20 0 6 2 5 78 1 2 3 4 5 20 0 6 2 5 2 9 6 6 A ...