Rev. Date: 3/14/18
Page 20
MODEL #500
Electrical Flowchart
(illustration T)
ELECTRICAL SYSTEM
General Operation:
(See illustration T for sequence and illustrations G,U,V and W for components)
This unit is powered by
one
or
two
separate input sources connected at the bottom of the Main Panel Box. Turning the Main
Disconnect Switch (
yellow
and
red
switch located on front of Main Control Panel) to the ON position distributes power to the
Terminal Boards of the Main Control Panel, Voltmeter, Kill Switch, and the Upper Terminals of the agitator (C4) and the blower
(C5) relays.
When the Kill Switch (
red
mushroom button) is released (closed) and the
green
Start Button is pressed, power is supplied to
the dropout relay(s) and the transformer. The transformer supplies 24 VAC to the 4-Position Selector Switch located on the
front of the Main Panel Box.
When the 4-Position Selector Switch is turned to MANUAL mode or the 4-Position Selector Switch is set to REMOTE mode
with remote control hand pendant switch closed, 24 VAC is supplied to the Pre-Alarm relay, sounding the alarm for a preset
time. After the alarm stops, 24 VAC powers the blower (C5) and/or agitator (C4) relays.
When the agitator (C4) relay is closed, power is also supplied to the 24 VAC ON/OFF Outlet on Main Control Panel. If power
is interrupted to this system by unplugging either main input cord(s), turning Main Disconnect Switch OFF, or pressing Kill
Switch; the
green
Start Button needs to be
pressed
to reactivate the system
after
power distribution into the system has
been reestablished. (See illustrations U, V & W for more details.)
Содержание 500
Страница 37: ...Rev Date 3 14 18 Page34 MODEL 500 NON SHREDDER UPPER HOPPER and LOWER BASE UNIT ASSEMBLY ...
Страница 40: ...Rev Date 3 14 18 Page37 MODEL 500 SHREDDER UPPER HOPPER and LOWER BASE UNIT ASSEMBLY ...
Страница 43: ...Rev Date 3 14 18 Page40 MODEL 500 BLOWER BOX ASSEMBLY ...
Страница 45: ...Rev Date 3 14 18 Page42 MODEL 500 MECHANICAL and ELECTRICAL CONTROL ASSEMBLY OPTIONS ...
Страница 47: ...Rev Date 3 14 18 Page44 MODEL 500 OPTIONALSHREDDERASSEMBLY HOPPEREXTENSION ...
Страница 58: ...Rev Date 3 14 18 Page55 MODEL 500 SERVICE RECORD DATE MAINTENANCE PERFORMED COMPONENTS REQUIRED ...