5. INSTALLATION
DESCRIPTION OF THE LABEL MARKINGS
The CYCLOMIX
TM
MICRO machine is fitted with 2 label markings : a label marking on the control bay and the
other one on the fluid module.
Marking label on the control bay
(bay located
outside
the spray booth)
Marking label on the fluid module
(fluid module located
outside
the spray booth
Æ
marking in accordance with the ATEX directive)
Marking in accordance with the ATEX directive
KREMLIN REXSON
STAINS FRANCE
Name and address of the manufacturer
CE
II 3 G
II
: group II
3
: class 3
Surface equipment meant to area where explosive atmospheres due to gas,
vapours, mists are not liable to appear from time to time in usual operating or
if they appear nevertheless, it is for a short duration.
G
: gas
Tension
CYCLOMIX
TM
MICRO machine voltage
P air : 6 bar / 87 psi
Maximum air pressure
P prod : 175 bar / 2536 psi
Maximum fluid pressure
Série / Serial
Number given by KREMLIN REXSON. The two first numbers indicate the
manufacturing year.
Ref
CYCLOMIX
TM
MICRO machine part number
Environmental Indication
(refer to § 2 - Environment)
Phase
Single phase
Fréquence
50-60Hz / Mains frequency
Ampérage
Maximum current used