KREMLIN REXSON
Page 11
Manual : 573.191.112
Caution!
The CYCLOMIX
TM
MICRO mixing machine must be installed outside the explosive area.
It must be installed in a safe area (non explosive area according to the ATEX directive).
The display unit must be moved 1 m / 3.3 ft away from the fluid module and not be
installed above that one.
The control bay must be connected to a mains supply fitted with a ground.
The ground of the fluid module must be grounded.
INSTALLATION DIAGRAM
A
Explosive area : area 1 (Z1) or area 2 (Z2)
(spray booth)
B
Non explosive area (safe area)
1A
CYCLOMIX
TM
MICRO control bay
1B
CYCLOMIX
TM
MICRO fluid module
2
Pumps + Accessories
The 1 m distance indicated in the diagram is given for your information only and
KREMLIN REXSON shall not be liable for it. The user is liable for the exact
delimitation of the zones which depends on the materials used, the material
environment and the use conditions (refer to EN 60079 -10 standard).
The 1 m distance can be adapted if the analysis the user carries out calls for it.