Parameters
Description
Factory
adjustment
For the 3
programs
Your
adjustment
Program 1
Your
adjustment
Program 2
Your
adjustment
Program 3
Handling of the error 6 in the
operating of the machine during the
production sequence (parameter
available for machine with serial
number > 14 V 1152).
Minimum value : 0 pulse
Maximum value : 5000 pulses
100 pulses
(Value of
origin)
PARAMETERS FOR MACHINE WITH CATALYST FLUSHING
Parameters
Description
Factory
adjustment
For the 3
programs
Your
adjustment
Program 1
Your
adjustment
Program 2
Your
adjustment
Program 3
Parameter of the password
Mixing ratio parameter. Percentage
of catalyst in the base, from 0% to
160%
50%
Parameters of the mixed fluid life
time
Minimum value : 1min
Maximum value : 480 min
100 min
Regeneration volume parameter in
cubic centimetre
Minimum value : 100 c.c
Maximum value : 10 000 c.c
5000 c.c
BASE
flushing volume during which
the machine flushes with solvent
Minimum value : 10 c.c
Maximum value : 10 000 c.c
500 c.c
CATA
flushing volume during which
the machine flushes with solvent
Minimum value : 10 c.c
Maximum value : 10 000 c.c
500 c.c
Mixing tolerance parameter to
enable the machine to make an
alarm.
Minimum value : 1%
Maximum value : 100%
5 %
Parameter of the fluid dry extract to
count the VOC
Minimum value : 0%
Maximum value : 100%
55 %