30
3.8.1
LCD Reports
At the main display level there’s a status line that displays general system status, date
and time. Date and time represents the last time there was a status change in one or
more internal modules of the RCI.
The modules are: Power, Channel, COM, USB and Printer. By scrolling up/down keys
user can see those statuses.
Besides those reports, the RCI5000 will also display channel monitor status and
interrogation results.
3.8.2
PC Reports
The codes for PC reports are:
Module
Fail Code
OK Code
PC serial port (COM)
A1
B1
USB A2
B2
Printer A3
B3
Power A6
B6
Channel A8
B8
MC2 C1
Channel monitor busy
Dx
Channel monitor restore from busy 8x
Channel monitor quiet
Ex
Channel monitor restore from quiet 9x
End unit OK
00
End unit not respond
AA
Notes:
-
All internal events that occurred without initiated check will be reported to serial port (COM)
of the PC as a message with account numbers, system number and message type zero.
-
‘x’ character in channel monitor section represents the channel number (1).
-
End unit status reports are the interrogation results. In this case the account and system
address will be the end unit address.