Annual cleaning of the burner system is required.
The burner assembly may be removed for easier
access. Refer to pages 34-35 in this installation
manual for complete instruction on removing &
reinstalling the burner assembly.
Visually check for blocked port holes, especially
near the pilot. Blocked port holes may cause de-
layed ignition.
Reinstall the burner assembly following instruc-
tions on page 35 of this installation manual.
Visually check pilot light and burner when in
operation. The flames should be steady, not lifting
or floating.
Annual examination of the venting system by a qualified agency is required.
IF THE VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY
REASON, RE-INSTALL PER THE INSTRUCTIONS PROVIDED WITH
THE INITIAL INSTALLATION.
The flow of combustion and ventilation air must not be obstructed.
The appliance is required to be inspected at least once a year by a
professional service person.
The compartment below the firebox (behind the lower grill) must be cleaned
at least once a year, more frequent cleaning may be required due to excessive
lint from carpeting, bedding materials, or other fibrous materials. It is im-
perative that the burner be cleaned once a year.
VENT SYSTEM
FAN
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE ONLY
BY QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD
BE INSPECTED BEFORE USE AND ANNUALLY BY A QUALI-
FIED SERVICE PERSON. MORE FREQUENT CLEANING MAY
BE REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING,
BEDDING MATERIALS, ETC. IT IS IMPERATIVE THAT CON-
TROL COMPARTMENTS, BURNERS AND CIRCULATION AIR
PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN.
IMPORTANT: ANY SAFETY SCREEN OR GUARD REMOVED FOR
SERVICING MUST BE REPLACED PRIOR TO OPERATING THE
APPLIANCE.
Burner Orifice
Clean glass only when cool and only with non-
abrasive cleansers.
Do not operate this fireplace with the glass/frame
assembly removed, cracked or broken.
The glass assembly, part #PRC-057T, shall only
be replaced as a complete unit, as supplied by
Hussong Mfg. Co., Inc.
Replacement of the glass & frame assembly,
part #PRC-057T, must only be performed by a
licensed or qualified service person.
DO NOT SUBSTITUTE MATERIALS.
Do not strike or slam glass door assembly.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER
AND DANGEROUS OPERATION. VERIFY PROPER OPERATION
AFTER SERVICING.
MAINTENANCE
CAUTION: KEEP THE APPLIANCE AREA CLEAR OF COMBUSTI-
BLE MATERIALS, SUCH AS GASOLINE AND OTHER FLAMMABLE
VAPORS AND LIQUIDS.
GLASS CLEANING & REPLACEMENT
MILLIVOLT BOARD SYSTEM
PAGE 52
The fan should be disconnected from electrical current, and cleaned
(vacuumed) every six months. The bearings are sealed and require no oiling.
PRC-36Pilot
Burner Ports
PRC-36-RF Pilot