OPTIONAL:
Disconnect ON/OFF rocker
switch wires from the back
of gas valve.
CAUTION: DO NOT CONNECT HIGH
VOLTAGE (115V) WIRE TO THE GAS
VALVE!
If
desired, a thermostat (wireless style also available), wall switch,
or remote control assembly may be used to turn the fireplace „OFF‟
and „ON‟. Only ONE of these may be installed. Follow instructions
included with each assembly.
WALL SWITCH / THERMOSTAT:
Run low-voltage (thermostat) wires from terminals on the gas valve to
the desired location of wall switch or thermostat.
Attach the appropriate connectors to wall switch / thermostat wires
and connect to the top and bottom terminals marked TH / TPTH on
the gas valve.
REMOTE CONTROL:
Follow instructions included with the remote control
.
IMPORTANT
:
The insulated cover included with the remote
control must be placed over the remote receiver to prevent
overheating.
IMPORTANT: If ON/OFF rocker switch wires are
not disconnected, the ON/OFF rocker switch on the
millivolt board must be in the „OFF‟ position for
proper operation of any of these components.
If rocker switch is „ON‟, the fireplace burner will operate until it is
turned „OFF‟ by the rocker switch. A wall switch, thermostat, or
remote control will not turn the fireplace „OFF‟ when it has been
turned „ON‟ by the rocker switch.
NOTE: The fireplace must be turned „ON‟ and
„OFF‟ by the same method. For example: If fire-
place is turned „ON‟ by the remote control, it must
be turned „OFF‟ by the remote control.
Remote Control Wiring Diagram
Thermostat Wiring Diagram
THERMOSTAT / WALL SWITCH / REMOTE (PRC-36 only)
NOTE: INSTALLATION OF THERMOSTAT OR WALL
SWITCH SHOULD ONLY BE DONE BY A QUALIFIED
INSTALLER
.