1. Insert fans through the lower grill opening, push to the back, posi-
tioning behind legs.
2. Connect fan wiring by attaching connectors on right fan onto termi-
nals on left fan.
3. From inside the lower right grill opening, loosen screw securing
removable access panel (with electrical box & romex connector
installed). Remove panel.
4. Insert 110V - 120V wiring (with ground) through romex connector
and wire to the speed control / receptacle assembly, matching the
black (hot), white (neutral), and green (ground) wires to the corre-
sponding wires on the speed control / receptacle assembly.
5. Secure speed control / receptacle assembly to the electrical box with
(2) screws provided.
6. Re-install electrical access panel. Tighten screw.
7. Attach the temperature control switch to the bottom of firebox.
8. Plug cord into the electrical box receptacle.
9. Turn speed control counter-
clockwise until it „clicks‟. This is the
„OFF‟ position.
10.
Turn speed control „ON‟ by turning knob clockwise past the „click‟
- this is the highest setting.
11. Re-install glass assembly. Refer to page 15 of this installation man-
ual if necessary.
12. Re-install lower grill, upper louver & upper hood. Refer to page 36
of this installation manual if necessary.
Before adjusting the temperature control switch, unplug the 3-prong
plug on the fan cord from the receptacle. Adjust position of the
temperature control switch to a warmer location under the firebox to
turn fan „ON‟ sooner or move it to a cooler location under firebox
to turn the fan „ON‟ later. The fan will turn on when the sensor in
the temperature control switch reaches 110° F and will turn „OFF‟
when the sensor reaches 90° F. After adjustment, plug the 3-prong
plug on fan cord into the receptacle
.
OPTIONAL FAN INSTALLATION (PRC-36 only)
PAGE 17
NOTE: Speed control / receptacle assembly & (3) wire
nuts are included in the fireplace components packet.
NOTE: This appliance must be electrically grounded and
connected in accordance with local codes, or in the ab-
sence of local codes, with the National Electrical Code,
ANSI/NFPA 70 Current Edition, or the Canadian electri-
cal Code CSA C22.1.
NOTE: This fan will not operate unless the speed control
has been turned „ON‟ and sufficient heat has been ap-
plied to the temperature control switch. The fan will
turn „ON‟ and „OFF‟ automatically as the fireplace heats
and cools. Adjust fan to desired speed while it is running.
TEMPERATURE CONTROL SWITCH POSITION
Temperature Control Switch (Looking through lower grill opening).