VENTING
NOTE: Horizontal sections require 1/4” (6 mm) rise for every
12” (305 mm) of travel.
HORIZONTAL TERMINATIONS
TYPICAL CORNER INSTALLATION
45° elbow + 90
˚
elbow + horizontal pipe + termination cap.
PAGE 23
90° ELBOW
Vent Opening Dimensions: Refer to vent pipe manufacturer's instructions.
VENTING DIMENSIONS FOR MINIMUM CORNER
INSTALLATIONS
HORIZONTAL
TERMINATION CAP
NOTE: Page 25 has information on restrictor installation in conjunction with
venting installation. Page 50 has information on restrictor recommendations
depending on burner flame appearance and instructions on installation after
venting is completed.
CAUTION: This gas appliance must not be connected to or joined
with any other chimney flue serving another appliance.
PIPE
45° ELBOW
THE KOZY HEAT WALL PASS-THRU, PART #800-WPT (4-1/2” (114 mm) - 6-1/2” (165 mm) WALL THICKNESS) OR #800-WPT2
(6-1/2” (165 mm) - 12-1/2” (318 mm) WALL THICKNESS), MUST BE USED ON ALL HORIZONTAL VENT RUNS.