L. COMPLETE THE INSTALLATION 

 

1.   THIS STEP SHOULD ONLY BE DONE BY A QUALIFIED INSTALLER OR SERVICE TECHNICIAN: 

 

A)  Perform lighting and shutdown procedures as described on pages #19-#20 for Model #CSK-335 and pages 

#22-#23 for Model #CSK-335-RF. This should be done prior to re-installing the glass so that any necessary 
adjustments can be made and proper operation and log position verified. 

 
 

 

2.   RE-INSTALL THE GLASS. Refer also to Figure L-1. 

Figure L-1

 
 

WARNING:

 DO NOT OPERATE THIS FIREPLACE 

WITH THE GLASS ASSEMBLY REMOVED, 
CRACKED, OR BROKEN. Replacement of the 
glass assembly should be done by a licensed or 
qualified service person. 

TWO GLASS LATCHES 

 

 
 
 
 
 
 
 
A.  Align the 2 slots in the top of the glass assembly over 

the 2 tabs on the fireplace (at the top). 

 
B.  Place the glass assembly so it is flush with the front of 

the fireplace front. 

 
C.  While holding the glass assembly, pull the latches out 

and secure over the glass latch clips on the bottom of 
the glass frame locking it in place. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

Left intentionally blank. 

Page 17

Содержание Chaska-XL

Страница 1: ...HASKA XL Direct Vent Gas Fireplace Insert INSTALLATION OPERATING MANUAL This appliance may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local cod...

Страница 2: ...eck millivolt board installation 13 Complete fan wiring installation Models CSK 335 CSK 335 RF 14 Assemble Attach The Shroud 15 Install the lower grill 15 Log Installation 16 Complete the Installation...

Страница 3: ...ed heating appliance or equipment The sign shall read in print size no less than inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS INSPECTION The state of local gas inspector of the...

Страница 4: ...ician to inspect this appliance and to replace any part of the control system and any gas control which has been under water Warning This Product Must be Installed By A Licensed Plumber or Gas Fitter...

Страница 5: ...Class A metal chimney 7 minimum inside diameter Masonry Chimney 6 x 8 minimum inside diameter MINIMUM OPENING DIMENSIONS Existing chimney height Minimum 12 ft Maximum 30 ft To Determine the length of...

Страница 6: ...panying the vent system as well as the venting requirements and instructions in this manual 2 Shroud 3 pc 4 pc Standard shrouds are available for this insert and will fit most applications Custom shro...

Страница 7: ...cal building codes IMPORTANT DO NOT RUN THE GAS LINE IN A MANNER THAT WOULD OBSTRUCT THE OPERATION OF THE FAN OR FAN COMPONENTS This fireplace is equipped with a 3 8 flexible gas line connection 18 lo...

Страница 8: ...d inlet incoming pressures are located in front of the gas valve The right pressure tap is the manifold pressure and the left pressure tap is the incoming pressure Follow instructions on page 21 for M...

Страница 9: ...es out then down to release from the clips on the glass assembly C Lift the glass assembly up off the tabs at the top of the firebox D Pull the bottom of the glass assembly out and remove E Set aside...

Страница 10: ...trical box romex connector installed from the right side of the fireplace Remove the panel 2 Remove the 2 screws securing the speed control receptacle to expose the wiring 3 Remove existing cord and i...

Страница 11: ...NG This appliance is equipped with a three prong grounding plug for protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove...

Страница 12: ...ength needed from the air duct on the insert to above the damper opening in the existing chimney Remove excess combustion air pipe from the end without the collar Continue with Step B 2 below B 1 Slid...

Страница 13: ...nd the top of the existing chimney Set the termination cap into position as instructed in the vent system installation manual OPTIONAL 816 CL kits Secure the termination cap to the existing chimney wi...

Страница 14: ...ure E 5 B Place a bead of sealant provided around the 3 exhaust pipe red marking and slide it inside the 3 collar marked Exhaust on the air duct Secure with 3 self tapping screws provided Apply additi...

Страница 15: ...at the top of the insert and sliding the air duct forward until it stops Figures F 2 F 3 3 Secure air duct to the insert at the front with 2 sheet metal screws included in the components packet Refer...

Страница 16: ...nning the gas line through the bottom IMPORTANT Do not run the incoming gas line in a manner that would obstruct the operation of the fan 3 Install the manual shut off valve included with this firepla...

Страница 17: ...g plug on the fan cord from the receptacle Adjust the position of the temperature control switch to a warmer location under the firebox to turn the fan ON sooner or move it to a cooler location under...

Страница 18: ...n the hood to the corresponding mounting holes on lower inside flange of the shroud top piece Secure with 2 3 8 phillips head screws A provided ATTACH THE SHROUD Figure J 2 1 Align the holes in the ta...

Страница 19: ...NT Push the logs down onto the mounting studs so that the logs will be setting on the burner assembly 2 Install ember logs CX4 CX5 in front of the burner as shown in Figure K 1 Figure K 1 Figure K 2 3...

Страница 20: ...GLASS Refer also to Figure L 1 Figure L 1 WARNING DO NOT OPERATE THIS FIREPLACE WITH THE GLASS ASSEMBLY REMOVED CRACKED OR BROKEN Replacement of the glass assembly should be done by a licensed or qual...

Страница 21: ...e marked TH Follow instructions included with the remote control CAUTION DO NOT CONNECT HIGH VOLTAGE 115V WIRE TO THE GAS VALVE IMPORTANT The insulated cover included with the remote control must be p...

Страница 22: ...air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air DUE TO HIGH SURFACE TEMPERATURES KEEP CHILDREN CLOTHING AND FURNITURE AWAY 2 BEFORE LI...

Страница 23: ...the setting on the thermostat or remote control NOTE The pilot will stay lit TO TURN THE PILOT OFF To turn off the pilot push in and turn the control knob to the OFF position DO NOT FORCE NOTE A PAINT...

Страница 24: ...re reading is within the normal range an incoming pressure check is not necessary A too high or too low pressure reading warrants an inlet incoming gas pressure check TO CHECK THE INLET PRESSURE 1 Loo...

Страница 25: ...se this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system which has been under water DO...

Страница 26: ...on the glass this is normal in all gas fireplaces and will disappear as the fireplace heats TO TURN THE BURNER OFF LOCAL SETTING Turn the control knob clockwise to the pilot position REMOTE SETTING Th...

Страница 27: ...en but do not remove the inlet tap captive screw 10 Attach a plastic tube with a 1 4 shell ID and connect the manometer 11 Turn on the gas supply at the manual valve 12 Check the inlet tap pressure 13...

Страница 28: ...FETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE CAUTION LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND...

Страница 29: ...res from the fan cord Note The wires will remain connected to the back of the gas valve Refer to wiring diagram Figure D 2 page 8 7 Remove the glass assembly refer to Figure C 1 page 6 Set aside on a...

Страница 30: ...e burner orifice and the 2 mounting holes to the mounting holes in the heat shield Secure with the sheet metal screws removed in step 9 page 26 Refer to Figure P 1 page 26 5 Re install the logs Refer...

Страница 31: ...spark when piezo Wire on back of piezo button is loose or off Push wire back into place button is depressed Wire from piezo to electrode is loose at electrode Reconnect wire Electrode moved out of po...

Страница 32: ...ct connected properly or turned to wrong setting and use ON OFF switch only See Figures M 1 M 2 page 18 Model CSK 335 5 Burner won t stay lit Generator wires loose on Reposition wires and tighten scre...

Страница 33: ...as Line Valve to Burner connection 700 108 Remote control RF Valve 700 235 Natural Gas orifice 35 700 109 Honeywell RF Pilot Assembly 700 250 LP Gas orifice 50 700 060 Flexible Pilot Tubing Valve to P...

Страница 34: ...will be void if the fireplace is not installed by a qualified installer and according to the installation instructions Use of unauthorized components will make this warranty null and void This limite...

Страница 35: ...o person is authorized to extend the time of this Lifetime warranty or to accept on Hussong Manufacturing Co Inc s behalf any additional obligation of liability connected with the unit Hussong Manufac...

Отзывы: