O. MAINTENANCE REQUIREMENTS
1.
The appliance should be inspected at least once a year
by a professional service person.
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE
ONLY BY A QUALIFIED SERVICE PERSON. THE
APPLIANCE SHOULD BE INSPECTED BEFORE USE AND
AT LEAST ANNUALLY BY A QUALIFIED SERVICE
PERSON. MORE FREQUENT CLEANING MAY BE
REQUIRED DUE TO EXCESSIVE LINT FROM
CARPETING, BEDDING MATERIALS, ETC. IT IS
IMPERATIVE THAT CONTROL COMPARTMENTS,
BURNERS AND CIRCULATION AIR PASSAGEWAYS OF
THE APPLIANCE BE KEPT CLEAN.
2.
The compartment below the firebox (behind the lower
grill) must be cleaned at least once a year, more
frequent cleaning may be required due to excessive lint
from carpeting, bedding materials, or other fibrous
materials. It is imperative that the burner be cleaned
once a year.
FAN
The fan should be disconnected from electrical current, and
cleaned (vacuumed) every six months. The bearings are
sealed and require no oiling.
VENT SYSTEM
Annual examination of the venting system by a qualified
agency is required.
IF THE VENT-AIR INTAKE SYSTEM IS DISASSEMBLED
FOR ANY REASON, REINSTALL PER THE
INSTRUCTIONS PROVIDED WITH THE INITIAL
INSTALLATION.
The flow of combustion and ventilation air must not be
obstructed.
IMPORTANT:
ANY SAFETY SCREEN OR GUARD
REMOVED FOR SERVICING MUST BE REPLACED PRIOR
TO OPERATING THE APPLIANCE.
CAUTION:
LABEL ALL WIRES PRIOR TO
DISCONNECTION WHEN SERVICING CONTROLS.
WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER
OPERATION AFTER SERVICING.
MILLIVOLT BOARD SYSTEM
1.
Annual cleaning of the burner is required. The burner
& cover assembly may be removed for easier access.
2.
Refer to pages #26-#27 for complete instruction on
removing & reinstalling the burner & cover assembly.
3.
Visually check for blocked port holes, especially near
the pilot. Blocked port holes may cause delayed
ignition.
4.
Replace the burner & cover following instructions on
pages #26-#27.
5.
Visually check the pilot light and burner when they are
burning. The flames
should be steady, not lifting or
floating.
GLASS CLEANING & REPLACEMENT
•
Clean glass only when cool and only with nonabrasive
cleansers.
•
Do not operate this fireplace with the glass/frame
assembly removed, cracked or broken.
•
The glass assembly, Part #CXL-057T, shall only be
replaced as a complete unit, as supplied by Hussong
Mfg. Co., Inc.
•
Replacement of the glass assembly, Part #CXL-057T,
must only be performed by a licensed or qualified
service person. DO NOT SUBSTITUTE MATERIALS.
•
Do not
strike or slam glass door assembly.
CAUTION:
KEEP THE APPLIANCE AREA CLEAR OF
COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND
OTHER FLAMMABLE VAPORS AND LIQUIDS.
CSK-335 Pilot
CSK-335-RF Pilot
Burner Orifice
Page 25