![kozy heat Chaska-XL Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/kozy-heat/chaska-xl/chaska-xl_installation-and-operating-manual_1999735032.webp)
PROBLEM
CAUSE
SOLUTION
4. Burner won't light.
Pilot not lit.
Relight pilot.
Regulator valve not turned “ON”.
Turn valve to "ON"
Rocker switch not turned “ON”. (Model CSK-335).
Depress switch.
Rocker switch wires not connected. (Model CSK-335). Check wiring diagram Figure Q-1
to ensure that all wires are secure.
Generator wires loose at regulator terminals
Reposition wire an tighten screws. See
Figures Q-1 & Q-2 for wiring instructions.
Generator wire grounded out
Nuts securing millivolt board may need
due to pinching of wires.
loosening to remove pinched wire.
Generator is not producing enough
Replace generator.
millivolts to operate burner.
Wall switch, remote control or thermostat not
Connect properly or disconnect
connected properly or turned to wrong setting.
and use ON/OFF switch only.
See Figures M-1 & M-2, page #18. (Model CSK-335).
5. Burner won't stay lit.
Generator wires loose on
Reposition wires and tighten screws
valve terminals.
See Figures Q-1 & Q-2 for wiring
instructions.
Generator wire grounded out
Nuts securing millivolt board may need
due to pinched wires.
loosening to remove pinched wire.
Generator is not producing enough
Check millivolt reading, replace
millivolts to sustain burner operation.
generator if necessary.
Refractory panels not positioned
Secure refractory panels with
against firebox.
high-temp sealant.
FAN
OUTLET
PRESSURE
TAP
INLET
PRESSURE
TAP
PIEZO
LED
GAS CONTROL KNOB
L1
(HOT)
L2
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD
PROTECTION AS REQUIRED.
WIRING DIAGRAM
Model CSK-335-RF
Figure Q-2
Page 29
BURNER
PILOT
BURNER
ASSEMBLY
PILOT TUBE
THERMOPILE
LEADWIRE
THERMOPILE LEADWIRE