4. If necessary, level the insert by threading the leveling bolts (included in the components packet) into the nuts
mounted in the bottom of the insert behind the lower air passage - 2 each side. See Figure F-5.
Figure F-5
LEVELING LEGS (2 PER SIDE)
G. Complete the gas line installation
:
1. This fireplace is designed to accept either a
⅜
" or ½" gas line approved for gas appliances. Consult local
building codes to properly size the gas supply line leading to a 3/8" reduction.
2. Run the gas line into the fireplace, preferably through the left gas line hole. A gas line knock-out is also
located in the outer bottom of the insert when running the gas line through the bottom.
IMPORTANT:
Do not run the incoming gas line in a manner that would obstruct the operation of the fan.
3. Install the manual shut off valve (included with this fireplace insert) upstream from the regulator.
4. Connect the flexible gas line (installed on the gas valve on the millivolt board) to the manual shut off valve.
H. Check millivolt board installation:
NOTE: Refer to pages #26 & #27 in this installation manual for complete millivolt board installation procedures.
1. Ensure that all (6) nuts are attached to the mounting studs, securing the millivolt board in position.
2. Verify that the burner venturi is properly positioned over the burner orifice and the burner /cover assembly is
secured to the burner heat shield.
3. Check all gas connection for leaks, whether field or factory made.
Page 13