![kozy heat Chaska-XL Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/kozy-heat/chaska-xl/chaska-xl_installation-and-operating-manual_1999735005.webp)
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating conditions
and was determined independently of any installed system.
THIS INSERT IS APPROVED FOR INSTALLATION IN MASONRY AND FACTORY-BUILT SOLID FUEL BURNING FIREPLACES.
CAUTION:
THIS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID-FUEL
BURNING APPLIANCE.
THE EXISTING FIREPLACE MUST MEET THE
FOLLOWING REQUIREMENTS:
1.
The existing fireplace & chimney must be in clean
and in good working order and constructed of non-
combustible materials.
5.
The minimum inside dimensions of the existing
fireplace must be:
Height (A): 23 1/2
"
Front Width (B): 33 1/2
"
Depth (C): 16 1/2
"
Back Width (D): 24 1/2
"
2.
A gas line must be able to be installed to the insert.
3.
Any chimney clean-outs must fit properly.
4.
Existing Chimney:
Class ‘A’ metal chimney: 7” minimum inside diameter.
Masonry Chimney: 6" x 8" minimum inside diameter.
MINIMUM OPENING DIMENSIONS
Existing chimney height:
Minimum: 12 ft.
Maximum: 30 ft.
To Determine the length of your existing chimney:
A)
Remove the chimney cap.
NOTE: It is helpful to have two people complete the
next step in determining chimney height:
B)
With one person at the fireplace and the other person
at the top of the chimney, measure from the base of
the fireplace to the top of the chimney. Subtract 23”
for the height of the insert. This is the total length of
co-linear flexible aluminum you will require.
ALL DIMENSIONS ARE MINIMUM REQUIREMENTS
MEASUREMENT FROM FIREPLACE BASE TO TOP OF CHIMNEY:_____
LESS 23
"
(HEIGHT OF FIREPLACE:
-23
"
.
TOTAL CHIMNEY LENGTH REQUIRED:
_____
MAX.
35 FT
MIN. 12 FT.
MAX. 35 FT.
6.
MINIMUM CLEARANCES FROM THE INSERT TO
COMBUSTIBLES:
•
Insert side to sidewall: 12"
•
Insert top to 9" mantel: 16"
•
Insert top to 3/4" trim: 12"
•
Bottom of insert to combustible floor in front: 6"
•
Bottom of insert underneath to combustible floor: 0"