For reverse Cycle Models:
You can choose bottom drainage. See the following
procedures to perform bottom drainage:
1. Take out the drain pan and screws (which provided
with your air conditioner accessory).
2. Install the drain pan at the bottom of the unit and secure
with screws .
3. Connect the drain hose to the outlet located at one
side of the drain pan. You can purchase the drain
hose or tubing locally to satisfy your particular needs
(Drain hose is not supplied and that needs to be locally
procured.)
RUBBER
PLUG
SCREW
DRAIN PAN
DRAIN
OUTLET
INsTALLATION INsTrUCTIONs
Select the best location
Over 50cm
About 10mm
FENCE
AWNING
75-150c
m
Over 50cm
About 10mm
FENCE
AWNING
75-150c
m
1. To avoid vibration and noise, make sure the unit is installed securely and firmly.
2. Install the unit where the sunlight does not shine directly on the unit. If the unit receives direct sunlight, build an awning
to shade the cabinet.
3. There should be no obstacle, such as a fence or wall, within 50cm from the back of the cabinet because it will
prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air
conditioner.
4 Install the unit a little obliquely outward not to leak the condensed water into the room (about 10mm or 1 / 4 bubble
with level).
5. Install the unit with its bottom portion 75~150cm above the floor level.
6. The power cord must be connected to an independent circuit. The yellow/green wire must be grounded.
CAUTION
All side louvers of the cabinet must remain exposed to the outside of the structure.
13