8
Parameter detail setup
68
© Copyright Reserved KONICS Co., Ltd.
If pressure range is -760mmHg to 3kg/cm
2
, and pressure transmitter outputs 4 to 20
㎃
, for 4
㎃
input it displays -760 mmHg, 8mA input is unit changing point. For 20
㎃
input, it displays
3kg/cm
2
.
Unit changing point = (
16
X+1.033
× Y) + 4
16
4 to 20
㎃
output interval
X
Max. pressure range value (Ex. For 760 to 3 kg/cm
2
, it is " 3 ". )
1.033
Converted value from 760 mmHg to kg/cm
2
unit value (same unit)
Y
Use pr 1.033 (Ex. Use pressure is ‘0’, Y is 1.033.)
4
Output value for zero, 4.00
㎃
Set range
In case Input Type(Input specification) is temperature sensor(thermocouple, RTD): None
↔
Difference
In case Input Type(Input specification) is analog(voltage, current): Linear
↔
Root
↔
Square
↔
Two Unit (Two Unit is activated for current input(0 to 20
㎃
, 4 to 20
㎃
).)
Factory default: None
Range
Unit changing
point (
㎃
)
-760mmHg to 1kg/cm2
12.130
-760mmHg to 5kg/cm2
6.740
-760mmHg to 10kg/cm2
5.498
-760mmHg to 15kg/cm2
5.031
-760mmHg to 20kg/cm2
4.786
-760mmHg to 25kg/cm2
4.635
-760mmHg to 30kg/cm2
4.533
-760mmHg to 35kg/cm2
4.459
Содержание krn100
Страница 1: ... Copyright Reserved KONICS Co Ltd i USER MANUAL ...
Страница 2: ...ii Copyright Reserved KONICS Co Ltd ...
Страница 12: ...Table of Contents xii Copyright Reserved KONICS Co Ltd ...
Страница 26: ...2 Specification 26 Copyright Reserved KONICS Co Ltd ...
Страница 28: ...3 Dimensions 28 Copyright Reserved KONICS Co Ltd ...
Страница 32: ...4 Connection 32 Copyright Reserved KONICS Co Ltd ...
Страница 45: ...7 Operation Copyright Reserved KONICS Co Ltd 45 7 Operation ...
Страница 52: ...7 Operation 52 Copyright Reserved KONICS Co Ltd 7 3 2 Parameter ...
Страница 54: ...7 Operation 54 Copyright Reserved KONICS Co Ltd ...
Страница 144: ...9 DAQMaster 144 Copyright Reserved KONICS Co Ltd ...
Страница 150: ...10 Maintenance 150 Copyright Reserved KONICS Co Ltd ...
Страница 153: ...11 Troubleshooting Copyright Reserved KONICS Co Ltd 153 ...
Страница 154: ......