8
Parameter detail setup
72
© Copyright Reserved KONICS Co., Ltd.
8.1.18
Filter Counter (The number of digital filter)
Designate the number of sampling which apply to digital filter.
When you set Filter Type(Input digital filter), this parameter is activated.
Set range: 1 to 128
Factory default: -
When the set value of input digital filter is ‘4’, it does moving average input sampling values for
0.1 sec (100ms) and displays this value.
D1=S1
D2 =
S1 + S2
2
, D3 =
S1 + S2 + S3
3
Display values of D1, D2, D3 is the initial operation before averaging 4 sampling values.
D4 =
S1 + S2 + S3 + S4
4
, D5 =
S2 + S3 + S4 + S5
4
D6 =
S3 + S4 + S5 + S6
4
, D7 =
S4 + S5 + S6 + S7
4
D8 =
S5 + S6 + S7 + S8
4
Содержание krn100