a
Peel and cut off the plastic wrapper (A) from around the inner wires.
b
Remove the water block — the brown glue-like substance (B) — from between
the wires.
Pull the water block off by hand. It should just crumble off.
Observe how the coloured Ethernet pairs are twisted around each other and how
the twist ratio is different for each Ethernet pair. The two twisted wires assist
in decreasing crosstalk. When splicing, try to keep the pairs twisted together
in the same way.
Caution
Do not untwist the pairs more than 0.5″ for 100 Mbps or 0.375″ for 1000 Mbps. A
pair untwisted more than half an inch can adversely affect the performance of
the entire cable.