Transducer arrays
For the principles, see
Blister and steel pipe arrangements
on page 34
The steel conduits must be designed to fit each individual vessel.
They are not included with the system delivery. The steel
conduits must therefore be both provided (or manufactured)
and installed by the installation shipyard. The number of steel
conduits depends on the chosen system configuration and the
internal diameter of the conduits.
• a 0.5° x 1° system (2 TX1 modules and 1 RX1 modules)
requires two Tx conduits and one Rx conduit.
• a 1° x 1° system (1 TX1 modules and 1 RX1 modules)
requires one Tx conduits and one Rx conduit.
• a 1° x 2° system (1 TX1 modules and 1 RX1 modules)
requires one Tx conduits and one Rx conduit.
• a 2° x 2° system (1 TX1 modules and 1 RX1 modules)
requires one common Tx and Rx conduit.
4.4.1 Logistics and references
Safety
- Refer to the general safety procedures.
Qualifications
- Mechanical workers
Ship location
- Dry dock
Special tools
- None
Drawings
on page 109
4.4.2 Procedure
How to mount the steel conduits
1
Design the steel conduits with appropriate length and
diameter to fit the echo sounder.
2
Mount the steel conduits from the vessel hull and up towards
the sonar room and the EM 710 Transceiver Unit.
• The steel conduit(s) should have an outer diameter
of approximately 219 mm and an inner diameter of
approximately 197.0 mm.
• The steel conduits are laid as required by the vessel
structure and the location of the blister and sonar room.
The conduits may be bent if required, but not more than
30 degrees. Note however that one or two sharp bends on
the conduits may require a larger diameter.
• The upper opening of the steel conduits should be above
the vessel’s water line. If the openings of these conduits
are under the water level, then special acceptances are
needed from the classification soc.
164851/C
37
Содержание EM 710
Страница 1: ...Installation Manual EM 710 Multibeam echo sounder ...
Страница 2: ......
Страница 3: ...Kongsberg EM 710 Multibeam echo sounder Installation Manual Kongsberg Maritime 164851 C June 2009 ...
Страница 44: ...Kongsberg EM 710 Figure 10 Transducer mounting principles 42 164851 C ...
Страница 63: ...Cable layout Figure 20 Transceiver Unit front view 0 5 x 1 degree 164851 C 61 ...
Страница 88: ...Kongsberg EM 710 Figure 42 Cable clamp Transceiver Unit cable clamp on page 133 86 164851 C ...
Страница 112: ...Kongsberg EM 710 10 1 Installation Drawings 10 1 1 0 5º mounting frame assembly TX module 110 164851 C ...
Страница 113: ...Installation drawings 164851 C 111 ...
Страница 114: ...Kongsberg EM 710 10 1 2 1 mounting frame assembly RX module 112 164851 C ...
Страница 115: ...Installation drawings 164851 C 113 ...
Страница 116: ...Kongsberg EM 710 10 1 3 2 mounting frame assembly TX RX module 114 164851 C ...
Страница 117: ...Installation drawings 164851 C 115 ...
Страница 118: ...Kongsberg EM 710 10 1 4 0 5 x 1 gondola 116 164851 C ...
Страница 119: ...Installation drawings 164851 C 117 ...
Страница 120: ...Kongsberg EM 710 10 1 5 Transducer TX1 Outline dimensions 118 164851 C ...
Страница 121: ...Installation drawings 164851 C 119 ...
Страница 122: ...Kongsberg EM 710 10 1 6 Transducer TX2 Outline dimensions 120 164851 C ...
Страница 123: ...Installation drawings 164851 C 121 ...
Страница 124: ...Kongsberg EM 710 10 1 7 Transducer RX1 Outline dimensions 122 164851 C ...
Страница 125: ...Installation drawings 164851 C 123 ...
Страница 126: ...Kongsberg EM 710 10 1 8 Transducer RX2 Outline dimensions 124 164851 C ...
Страница 127: ...Installation drawings 164851 C 125 ...
Страница 128: ...Kongsberg EM 710 10 1 9 HWS Operator Station Outline dimensions 126 164851 C ...
Страница 129: ...Installation drawings 10 1 10 Transceiver Unit Outline dimensions 164851 C 127 ...
Страница 130: ...Kongsberg EM 710 128 164851 C ...
Страница 131: ...Installation drawings 10 1 11 Transceiver Unit 2 x 2 degree system Outline dimensions 164851 C 129 ...
Страница 132: ...Kongsberg EM 710 130 164851 C ...
Страница 133: ...Installation drawings 10 1 12 Transceiver Unit mounting bracket 164851 C 131 ...
Страница 134: ...Kongsberg EM 710 10 1 13 Junction Box outline dimensions 132 164851 C ...
Страница 135: ...Installation drawings 10 1 14 Transceiver Unit cable clamp 164851 C 133 ...
Страница 153: ...Installation drawings 164851 C 151 ...
Страница 155: ...EM 710 Multibeam echo sounder Installation manual EM 710 Multibeam echo sounder Maintenance manual ...