Maintenance and Troubleshooting
19 04 272 - 01.01.2012
Operating Instructions - Translation
Eng - 15/20
8.1 Maintenance
Perform the maintenance procedures according to the instructions described in the
following table.
Damages should be repaired by a specialist or by your wholesaler.
When
Where
What to do ?
Immediately
Exhaust filter splashed or
soaked with oil (can
promote smoke)
Change exhaust filter
Plexiglas cover
Replace if cover shows signs of
cracks, hairline cracks, deep
scratches or any other damage
Area under the sealing bar
(brass contact surface)
Clean it if sealing presents low
quality
Before starting
operation
Cable
Change if damaged
Vacuum chamber
To be cleaned
Silicon rubber Teflon band
Cover gasket
To be cleaned
Change if damaged
Sealing bar and cylinder
(piston rod)
Check functioning of cylinders
If necessary , grease it
(Lubricant: sewing-machine oil)
When
Where
What to do ?
Weekly
Area under the sealing
bar
(brass contact surface)
To be cleaned
Sealing cylinder piston
rod
To be cleaned
Complete machine
Turn on the machine and keep it for
30 minutes at operating temperature,
(or select service program – choice
VAC level P)
through this procedure water present
in the machine oil is removed. To
achieve operating temperature
operate the machine without product.
Oil level display
Control oil level and quality
If necessary, refill machine with oil
(oil type, see Chapter 5: “Technical
Data”)
After 6 months
Pump
Proceed oil change
Once a year
Exhaust filter
Change exhaust filter
Change exhaust filter earlier if there
is: strong soiling or pollution, higher
power consumption, higher
temperature or reduced cutting effect