SERVICE PROCEDURE
MAINTENANCE
4-52
CLEAN TRANSFER CASE BREATHER
4
1.
Remove cover (1).
2.
Remove the mud and dirt from around the breather (2),
then remove breather (2).
After removing the breather, take steps to prevent dirt or
dust from entering the mount.
3.
Soak the breather (2) in washing liquid and wash it.
Содержание WA320-5H